{"product_id":"hytera-hr1062-digital-dmr-repeater","title":"Hytera HR1062 Digital DMR Repeater for Hytera HP782","description":"\u003ch2 data-path-to-node=\"3\"\u003eDigital DMR Repeater with Space-Saving 1U Form Factor\u003c\/h2\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eHigh-Capacity 50-Watt Continuous Duty Base Station Infrastructure\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eDeploy a 100% continuous duty cycle digital backbone to double channel capacity and secure mission-critical fleet communications.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe genuine \u003cb data-path-to-node=\"6\" data-index-in-node=\"12\"\u003eHytera HR1062\u003c\/b\u003e is a professional-grade \u003cb data-path-to-node=\"6\" data-index-in-node=\"50\"\u003eHytera HR1062 Digital DMR Repeater for Hytera HP782\u003c\/b\u003e base station infrastructure engineered to extend the coverage footprint of local two-way radio networks. Integrating the \u003cb data-path-to-node=\"6\" data-index-in-node=\"223\"\u003eHytera HR1062\u003c\/b\u003e into your server rack establishes two simultaneous voice pathways on a single licensed frequency channel via DMR Tier II TDMA technology. This state-of-the-art base module operates seamlessly in analog, digital, or automatic mixed-mode configurations to facilitate a clean migration path from legacy hardware.\u003c\/p\u003e\n\u003cp\u003eSpecially developed for industrial production facilities, corporate campuses, security teams, and public safety dispatch networks, the \u003cb data-path-to-node=\"7\" data-index-in-node=\"135\"\u003eHytera HR1062\u003c\/b\u003e resolves the problem of signal dropouts and dead zones in high-rise concrete structures or vast geographic fields. The slim cabinet design incorporates an internal AC\/DC switching power supply module directly within the chassis frame to eliminate bulky external brick adapters. To guarantee uncompromised service continuity during sudden municipal grid blackouts, users can attach an external 13.6V backup battery directly to the dedicated rear DC port for automatic redundancy switching.\u003c\/p\u003e\n\u003cp\u003eEfficient heat dissipation is managed through a multi-stage heat sink layout paired with an intelligent variable-speed cooling fan that pulls front-to-back airflow across internal components. Advanced communication privacy parameters are natively supported via basic encryption protocols, with advanced AES256 structural encryption algorithms accessible through factory software license activations. Programming and codeplug adjustments require specialized customer programming software and a matching rear-port data link cable to align the station precisely with your local frequency coordination certificates.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eComprehensive Fleet Integration:\u003c\/b\u003e Engineered to deliver reliable wide-area voice routing as a \u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"93\"\u003eHytera HR1062 Digital DMR Repeater for Hytera HP782\u003c\/b\u003e hub.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eSpace-Saving 1U Chassis:\u003c\/b\u003e Half the height of traditional repeating base stations, allowing administrators to optimize dense server room racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eAC\/DC Power Redundancy:\u003c\/b\u003e Natively supports concurrent AC and DC connections to execute instant, interruption-free switching during power failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eAnalog and Digital Auto Switch:\u003c\/b\u003e Automatically identifies the incoming modulation format and repeats the signal cleanly to support mixed radio fleets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003e100% Continuous Duty Cycle:\u003c\/b\u003e Employs front-to-back variable cooling fan ventilation to safely handle constant 50-Watt transmissions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"12\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,1,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,1,1,0\"\u003eHytera\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,2,0,0\"\u003eModel\/SKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,2,1,0\"\u003e\u003cb data-path-to-node=\"12,2,1,0\" data-index-in-node=\"0\"\u003eHytera HR1062\u003c\/b\u003e (HR1062)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,3,0,0\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,3,1,0\"\u003eDMR Digital Repeater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,4,0,0\"\u003eFrequency Band\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,4,1,0\"\u003eVHF \/ UHF (Variant Dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,5,0,0\"\u003eFrequency Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e136–174 MHz (VHF) \/ 400–470 MHz (UHF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,6,0,0\"\u003ePower Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,6,1,0\"\u003e5–50 Watts (Adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,7,0,0\"\u003eCapacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,7,1,0\"\u003e64 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,8,0,0\"\u003eDuty Cycle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,8,1,0\"\u003e100% Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,9,0,0\"\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,9,1,0\"\u003eAC 100–120V \/ DC 13.6V ±15%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,10,0,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,10,1,0\"\u003e1 3\/4 x 19 x 14 3\/4 Inches (1U)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,11,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,11,1,0\"\u003e17 lbs 10 oz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,12,0,0\"\u003eNetworking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,12,1,0\"\u003eDMR Tier II, IP Site Connect, XPT Trunking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eModel Variations\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"14\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,1,0,0\"\u003e\u003cb data-path-to-node=\"14,1,0,0\" data-index-in-node=\"0\"\u003eHR1062-U1\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,1,1,0\"\u003eUHF 400–470 MHz frequency model configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,2,0,0\"\u003e\u003cb data-path-to-node=\"14,2,0,0\" data-index-in-node=\"0\"\u003eHR1062-V1\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"14,2,1,0\"\u003eVHF 136–174 MHz frequency model configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eCompatibility\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"17\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,1,0,0\"\u003eHP602\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,1,1,0\"\u003eHP682\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,1,2,0\"\u003eHP702\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,1,3,0\"\u003eHP782\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,2,0,0\"\u003eHM782\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,2,1,0\"\u003ePD502i\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,2,2,0\"\u003ePD562i\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,2,3,0\"\u003ePD602i\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,3,0,0\"\u003ePD662i\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,3,1,0\"\u003ePD682i\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,3,2,0\"\u003ePD702i\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,3,3,0\"\u003ePD782i\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,4,0,0\"\u003eMD612i\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,4,1,0\"\u003eMD622i\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,4,2,0\"\u003eMD782i\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"17,4,3,0\"\u003eMNC360\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eWhat's Included\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"19\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\/Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,0,0\"\u003e1U Digital DMR Base Station Repeater\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,1,0\"\u003e\u003cb data-path-to-node=\"19,1,1,0\" data-index-in-node=\"0\"\u003eHytera HR1062\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,2,0\"\u003e✅ Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,0,0\"\u003eStandard AC Power Supply Cable Line\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,1,0\"\u003ePWC03\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,2,0\"\u003e✅ Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,0,0\"\u003eStandard 10-Foot DC Power Input Harness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,1,0\"\u003ePWC06\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,2,0\"\u003e✅ Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,0,0\"\u003eFactory User Operational Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,1,0\"\u003eDocumentation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,2,0\"\u003e✅ Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,5,0,0\"\u003eInternal Duplexer Hardware Module\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,5,1,0\"\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,5,2,0\"\u003e❌ Sold Separately\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,6,0,0\"\u003eMobile Palm Microphone Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,6,1,0\"\u003eSM16A1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,6,2,0\"\u003e❌ Sold Separately\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul data-path-to-node=\"21\"\u003e\n\u003cli\u003eHytera HP782 DMR Portable Two-Way Radio (\u003ca href=\"https:\/\/www.atlanticradiocorp.com\/products\/hp782-hytera\" title=\"Hytera HP782 \"\u003eHP782\u003c\/a\u003e) — The primary high-tier digital handheld transceiver that leverages this repeater architecture for extended wide-area coverage.\u003c\/li\u003e\n\u003cli\u003eHytera PC152 USB Programming Cable (\u003cmeta charset=\"utf-8\"\u003e\n\u003ca href=\"https:\/\/www.atlanticradiocorp.com\/products\/pc152-hytera\" title=\"PC152\"\u003e\u003cspan data-path-to-node=\"14,1,1,0\"\u003ePC152\u003c\/span\u003e\u003c\/a\u003e) — The essential data interface cable required to connect the repeater assembly to computer terminals for custom software profiling.\u003c\/li\u003e\n\u003cli\u003eHytera SM16A1 Hand Palm Microphone (\u003cmeta charset=\"utf-8\"\u003e\n\u003ca href=\"https:\/\/www.atlanticradiocorp.com\/products\/sm16a1-hytera\" title=\"SM16A1\"\u003e\u003cspan data-path-to-node=\"14,3,1,0\"\u003eSM16A1\u003c\/span\u003e\u003c\/a\u003e) — A commercial-grade handheld palm microphone that attaches to the front port for local testing and direct diagnostic dispatching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"22\"\u003eMore Resources\u003c\/h3\u003e\n\u003cul data-path-to-node=\"23\"\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(0, 113, 181);\"\u003e\u003ca style=\"color: #0071b5; text-decoration: underline;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0062\/0845\/4744\/files\/Hytera_HR1062_Brochure.pdf?v=1645554552\" title=\"HM1062 Brochure\" rel=\"noopener\" target=\"_blank\"\u003eHR1062 Brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/www.google.com\/search?q=https:\/\/atlanticradiocorp.com\/blogs\/news\/guide-to-two-way-radio-repeaters\" class=\"ng-star-inserted\" target=\"_blank\"\u003eGuide to Two-Way Radio Repeaters\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"25\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4 data-path-to-node=\"26\"\u003eCan this repeater operate concurrently with an existing legacy analog radio system?\u003c\/h4\u003e\n\u003cp\u003eYes, the \u003cb data-path-to-node=\"27\" data-index-in-node=\"9\"\u003eHytera HR1062\u003c\/b\u003e features an advanced mixed-mode channel algorithm that automatically senses whether an incoming transmission is analog or digital and repeats the audio in the identical format.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"28\"\u003eDoes this rack-mount unit require an external power adapter to plug into a wall?\u003c\/h4\u003e\n\u003cp\u003eNo, the \u003cb data-path-to-node=\"29\" data-index-in-node=\"8\"\u003eHytera HR1062\u003c\/b\u003e is engineered with a built-in AC\/DC power supply module mounted directly inside its 1U frame, letting you connect the standard AC power cord straight into any wall outlet.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"30\"\u003eHow does the automatic power redundancy system work during an active blackout?\u003c\/h4\u003e\n\u003cp\u003eWhen you hook up a 12V external lead-acid or backup battery line to the rear DC power terminals, the internal circuit tracking board will instantaneously bridge power over to the battery source if AC grid connectivity drops.\u003c\/p\u003e\n\u003cp data-path-to-node=\"31\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"32\"\u003eWarranty\u003c\/h3\u003e\n\u003cp data-path-to-node=\"33\"\u003e2-year manufacturer's warranty.\u003c\/p\u003e","brand":"Hytera","offers":[{"title":"HR1062-U1","offer_id":42014423023790,"sku":"HR1062-U1","price":2990.97,"currency_code":"USD","in_stock":true},{"title":"HR1062-V1","offer_id":42014423056558,"sku":"HR1062-V1","price":2990.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0062\/0845\/4744\/products\/hr1062-radio-repeaters-911366.jpg?v=1691990889","url":"https:\/\/www.atlanticradiocorp.com\/products\/hytera-hr1062-digital-dmr-repeater","provider":"Atlantic Radio Communications Corp. ","version":"1.0","type":"link"}